Reference health

Multi-Parameter Optical Fiber Sensing of Gaseous Ammonia and Carbon Dioxide

https://doi.org/10.1109/jlt.2019.2953271
CiteStamped reference-health badge
31/31 checkable references clean · checked 2026-07-22

Every reference with a DOI in the deposited reference list resolved to a known work in Crossref or DataCite at the dated check, and none carried a retraction, withdrawal, or removal notice.

4 without a DOI — not checked. A reference deposited without a DOI is never matched by title or guessed at; it stays outside the checked set, and this line discloses that.

The 31 checked references that resolve
resolves10.1364/OME.7.001858
Room temperature ammonia sensor using side-polished optical fiber coated with graphene/polyaniline nanocomposite
resolves10.1016/j.snb.2005.02.015
Optical fiber-based evanescent ammonia sensor
resolves10.1016/j.snb.2017.09.041
Carbon dioxide measurements using long period grating optical fibre sensor coated with metal organic framework HKUST-1
resolves10.3390/s18124393
All-Fiber CO2 Sensor Using Hollow Core PCF Operating in the 2 µm Region
resolves10.1117/12.2539566
Optical fibre temperature sensor based on thermochromic liquid crystal
resolves10.3390/proceedings2131041
Optical Ammonia Sensor for Continuous Bioprocess Monitoring
resolves10.1021/ac00116a021
Dual-Analyte Fiber-Optic Sensor for the Simultaneous and Continuous Measurement of Glucose and Oxygen
resolves10.1021/la403667q
Dip Biosensor Based on Localized Surface Plasmon Resonance at the Tip of an Optical Fiber
resolves10.2460/ajvr.1991.52.10.1723
Association of environmental air contaminants with disease and productivity in swine
resolves10.1038/ki.1997.324
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
resolves10.1088/1752-7155/5/3/037108
Clinical study of multiple breath biomarkers of asthma and COPD (NO, CO <sub>2</sub> , CO and N <sub>2</sub> O) by infrared laser spectroscopy
resolves10.1128/CMR.00054-05
Pathogenesis of<i>Helicobacter pylori</i>Infection
resolves10.3390/metabo4020465
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
resolves10.1016/j.ijms.2004.08.010
Applications of breath gas analysis in medicine
resolves10.4103/2229-5186.79345
Methods for the determination of limit of detection and limit of quantitation of the analytical methods
resolves10.1016/j.snb.2018.05.109
Highly sensitive label-free antibody detection using a long period fibre grating sensor
resolves10.1021/ja963442c
Assembling Alternate Dye−Polyion Molecular Films by Electrostatic Layer-by-Layer Adsorption
resolves10.1007/0-306-47058-6_7
Fluorescence-Based Fiber-Optic Sensors
resolves10.1088/1464-4258/5/5/355
Optical fibre instrumentation for environmental monitoring applications
resolves10.3390/s151229890
Study on the Sensing Coating of the Optical Fibre CO2 Sensor
resolves10.1088/2040-8986/aac68d
Biomedical application of optical fibre sensors
resolves10.1364/OL.27.001385
Relative humidity sensor with optical fiber Bragg gratings
resolves10.1038/nbt0695-597
A Fiber-Optic Carbon Dioxide Sensor for Fermentation Monitoring
resolves10.1016/0924-4247(94)00948-H
A distributed optical-fibre sensing system for multi-point humidity measurement
resolves10.1016/j.snb.2016.12.050
Multi-parameter measurements using optical fibre long period gratings for indoor air quality monitoring
resolves10.3390/s151025208
Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors
resolves10.1080/10408340600976499
Current Status of Methods and Techniques for Breath Analysis
resolves10.3390/s140304060
A Fiber Optic Ammonia Sensor Using a Universal pH Indicator
resolves10.1016/j.sbsr.2018.100254
A reflection-mode fibre-optic sensor for breath carbon dioxide measurement in healthcare
resolves10.1016/j.jphotochemrev.2006.04.002
Porphyrin photochemistry in inorganic/organic hybrid materials: Clays, layered semiconductors, nanotubes, and mesoporous materials
The 4 references without a DOI — listed, not checked
no DOI — not checkedref36
no DOI — not checkedToxicological profile for ammonia
no DOI — not checkedNanoassembled thin-film gas sensor II. An intrinsic highly sensitive fibre-optic sensor for ammonia detection
no DOI — not checkedA preliminary test for skin gas assessment using a porphyrin based evanescent wave optical fiber sensor
What this badge says. CiteStamped means the CHECKABLE references of this work were clean at the dated check: each resolved to a known work in a public registry, and none carried a retraction notice at that time. It says nothing about the quality, findings, or importance of the work itself, and nothing about references deposited without a DOI.

checked 2026-07-22 — re-checked daily as this page is visited; titles and statuses come from Crossref and DataCite and are not part of the signed record

Embed this badge

Both snippets point at the live badge image and link back to this page. The badge re-renders from the daily check, so an embed never goes stale by more than a day of visits.

<a href="https://citestamp.com/citestamped/10.1109/jlt.2019.2953271"><img src="https://citestamp.com/citestamped/10.1109/jlt.2019.2953271/badge.svg" alt="CiteStamped reference-health badge" width="460" height="64"></a>
[![CiteStamped reference-health badge](https://citestamp.com/citestamped/10.1109/jlt.2019.2953271/badge.svg)](https://citestamp.com/citestamped/10.1109/jlt.2019.2953271)