Reference health

APPLICATION OF GLUTAMATE-SENSITIVE BIOSENSOR FOR ANALYSIS OF FOODSTUFF

https://doi.org/10.15407/biotech11.04.057
CiteStamped reference-health badge
25/25 checkable references clean · checked 2026-07-23

Every reference with a DOI in the deposited reference list resolved to a known work in Crossref or DataCite at the dated check, and none carried a retraction, withdrawal, or removal notice.

2 without a DOI — not checked. A reference deposited without a DOI is never matched by title or guessed at; it stays outside the checked set, and this line discloses that.

The 25 checked references that resolve
resolves10.1093/jn/125.11.2891S
Executive Summary from the Report: Analysis of Adverse Reactions to Monosodium Glutamate (MSG)
resolves10.1016/S0003-2670(99)00533-4
Microplate-based fluorometric methods for the enzymatic determination of l-glutamate: application in measuring l-glutamate in food samples
resolves10.1093/jn/130.4.1007S
Glutamate as a Neurotransmitter in the Brain: Review of Physiology and Pathology
resolves10.1016/S0378-4347(97)00314-9
Capillary electrophoresis of glutamate and aspartate in rat brain dialysate Improvements in detection and analysis time using cyclodextrins
resolves10.1039/AN9881300715
Titrations in non-aqueous media. Part X. Potentiometric and conductimetric titrations of amino acids with tetrabutylammonium hydroxide in pyridine and acetonitrile solvents
resolves10.1016/S0165-0270(02)00201-7
In vivo microdialysis and gas-chromatography/mass-spectrometry for 13C-enrichment measurement of extracellular glutamate in rat brain
resolves10.1006/abio.1998.2650
A Continuous Spectrophotometric Method Based on Enzymatic Cycling for Determiningl-Glutamate
resolves10.1111/j.1470-8744.1987.tb00479.x
Use of A Bioreactor Consisting of Sequentially Aligned L‐Glutamate Dehydrogenase and L‐Glutamate Oxidase for the Determination of Ammonia by Chemiluminescence
resolves10.1039/an9962101305
Flow injection methods for determination of L-glutamate using glutamate decarboxylase and glutamate dehydrogenase reactors with spectrophotometric detection
resolves10.1016/0039-9140(91)80008-N
Amperometric enzyme electrodes for the determination of l-glutamate
resolves10.1016/S0956-5663(99)00041-X
NADH and glutamate on-line sensors using Os-gel-HRP/GC electrodes modified with NADH oxidase and glutamate dehydrogenase
resolves10.1016/S0141-0229(00)00242-8
The preparation and characterization of an immobilized l-glutamic decarboxylase and its application for determination of l-glutamic acid
resolves10.1080/00021369.1984.10866090
Methods for Determining<scp>L</scp>-Glutamate in Soy Sauce with<scp>L</scp>-Glutamate Oxidase
resolves10.1016/0168-1656(95)00058-X
l-Glutamate biosensor using a novel l-glutamate oxidase and its application to flow injection analysis system
resolves10.1016/0003-2670(93)80221-6
A mediated amperometric enzyme electrode using tetrathiafulvalene and l-glutamate oxidase for the determination of l-glutamic acid
resolves10.1016/S0003-2670(00)84651-6
Comparison of two fibre-optic l-glutamate biosensors based on the detection of oxygen or carbon dioxide, and their application in combination with flow-injection analysis to the determination of glutamate
resolves10.1016/j.snb.2011.10.066
Optical biosensor test strip for the screening and direct determination of l-glutamate in food samples
resolves10.1016/S0956-5663(98)00046-3
High-throughput flow-injection analysis of glucose and glutamate in food and biological samples by using enzyme/polyion complex-bilayer membrane-based electrodes as the detectors
resolves10.1016/j.foodchem.2008.06.043
A non-plasticized chitosan based solid state electrode for flow injection analysis of glutamate in food samples
resolves10.1016/j.aca.2018.03.015
An amperometric glutamate biosensor for monitoring glutamate release from brain nerve terminals and in blood plasma
resolves10.1016/j.talanta.2014.12.031
Monitoring of the velocity of high-affinity glutamate uptake by isolated brain nerve terminals using amperometric glutamate biosensor
resolves10.1016/j.electacta.2008.03.076
Characterization of permselective coatings electrosynthesized on Pt–Ir from the three phenylenediamine isomers for biosensor applications
resolves10.1021/ac5006553
Amperometric Biosensor System for Simultaneous Determination of Adenosine-5′-Triphosphate and Glucose
resolves10.1186/s11671-017-2353-9
Improvement of amperometric transducer selectivity using nanosized phenylenediamine films
resolves10.1023/A:1005694704872
Comparative study of hydrogel-immobilized l-glutamate oxidases for a novel thick-film biosensor and its application in food samples
The 2 references without a DOI — listed, not checked
no DOI — not checked2. Ghobadi S., Gorton L. Bienzyme Carbon Paste Electrodes for L-Glutamate Determination. Curr. Sep. 1996, 4, 94–102.
no DOI — not checked10. Lateef M., Siddiqui K., Saleem M., Iqbal L. Estimation of Monosodium Glutamate by Modified HPLC Method in Various Pakistani Spices Formula. J. Chem. Soc. Pak. 2012, 34 (1), 39–42.
What this badge says. CiteStamped means the CHECKABLE references of this work were clean at the dated check: each resolved to a known work in a public registry, and none carried a retraction notice at that time. It says nothing about the quality, findings, or importance of the work itself, and nothing about references deposited without a DOI.

checked 2026-07-23 — re-checked daily as this page is visited; titles and statuses come from Crossref and DataCite and are not part of the signed record

Embed this badge

Both snippets point at the live badge image and link back to this page. The badge re-renders from the daily check, so an embed never goes stale by more than a day of visits.

<a href="https://citestamp.com/citestamped/10.15407/biotech11.04.057"><img src="https://citestamp.com/citestamped/10.15407/biotech11.04.057/badge.svg" alt="CiteStamped reference-health badge" width="460" height="64"></a>
[![CiteStamped reference-health badge](https://citestamp.com/citestamped/10.15407/biotech11.04.057/badge.svg)](https://citestamp.com/citestamped/10.15407/biotech11.04.057)