One-Step Calibration of AFM in Liquid

https://doi.org/10.3389/fphy.2020.00301
CiteStamped reference-health badge
25/25 checkable references clean · checked 2026-07-22

Every reference with a DOI in the deposited reference list resolved to a known work in Crossref or DataCite at the dated check, and none carried a retraction, withdrawal, or removal notice.

1 without a DOI — not checked. A reference deposited without a DOI is never matched by title or guessed at; it stays outside the checked set, and this line discloses that.

The 25 checked references that resolve
resolves10.1038/s42254-018-0001-7
Atomic force microscopy-based mechanobiology
resolves10.1063/1.1143970
Calibration of atomic-force microscope tips
resolves10.1088/0957-4484/6/1/001
Calculation of thermal noise in atomic force microscopy
resolves10.1063/1.3100258
Atomic force microscopy spring constant determination in viscous liquids
resolves10.1063/1.4864086
Uncertainty in least-squares fits to the thermal noise spectra of nanomechanical resonators with applications to the atomic force microscope
resolves10.1063/1.3455217
Power spectrum analysis with least-squares fitting: Amplitude bias and its elimination, with application to optical tweezers and atomic force microscope cantilevers
resolves10.1088/0957-4484/7/3/014
Determination of the spring constants of probes for force microscopy/spectroscopy
resolves10.1063/1.1144209
A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy
resolves10.1063/1.1150021
Calibration of rectangular atomic force microscope cantilevers
resolves10.1063/1.1145292
Parallel beam approximation for V-shaped atomic force microscope cantilevers
resolves10.1063/1.4757398
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
resolves10.1088/0957-4484/14/1/301
Comparison of calibration methods for atomic-force microscopy cantilevers
resolves10.1063/1.368002
Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope
resolves10.1063/1.4962866
A virtual instrument to standardise the calibration of atomic force microscope cantilevers
resolves10.1063/1.2162455
Noninvasive determination of optical lever sensitivity in atomic force microscopy
resolves10.1038/s41598-017-05383-0
Standardized Nanomechanical Atomic Force Microscopy Procedure (SNAP) for Measuring Soft and Biological Samples
resolves10.1007/s12551-019-00585-4
High-speed force spectroscopy: microsecond force measurements using ultrashort cantilevers
resolves10.1016/j.ultramic.2011.09.012
Interlaboratory round robin on cantilever calibration for AFM force spectroscopy
resolves10.1063/1.3661130
Note: Curve fit models for atomic force microscopy cantilever calibration in water
resolves10.1016/s0304-3991(00)00077-2
Thermomechanical noise of a free v-shaped cantilever for atomic-force microscopy
resolves10.1021/la047670t
Comment on Tilt of Atomic Force Microscope Cantilevers:  Effect on Spring Constant and Adhesion Measurements
resolves10.1088/0957-4484/15/9/039
Finite optical spot size and position corrections in thermal spring constant calibration
resolves10.1063/1.5063992
Eliminating the effect of acoustic noise on cantilever spring constant calibration
resolves10.1140/epje/i2002-10096-x
Hydrodynamic interaction of AFM cantilevers with solid walls: An investigation based on AFM noise analysis
resolves10.1063/1.2336115
Precision and accuracy of thermal calibration of atomic force microscopy cantilevers
The 1 reference without a DOI — listed, not checked
no DOI — not checkedApplication note 94: practical advice on the determination of cantilever spring constants
What this badge says. CiteStamped means the CHECKABLE references of this work were clean at the dated check: each resolved to a known work in a public registry, and none carried a retraction notice at that time. It says nothing about the quality, findings, or importance of the work itself, and nothing about references deposited without a DOI.

checked 2026-07-22 — re-checked daily as this page is visited; titles and statuses come from Crossref and DataCite and are not part of the signed record

Embed this badge

Both snippets point at the live badge image and link back to this page. The badge re-renders from the daily check, so an embed never goes stale by more than a day of visits.

<a href="https://citestamp.com/citestamped/10.3389/fphy.2020.00301"><img src="https://citestamp.com/citestamped/10.3389/fphy.2020.00301/badge.svg" alt="CiteStamped reference-health badge" width="460" height="64"></a>
[![CiteStamped reference-health badge](https://citestamp.com/citestamped/10.3389/fphy.2020.00301/badge.svg)](https://citestamp.com/citestamped/10.3389/fphy.2020.00301)