On the public citation graph

New direct torque control of DFIG under balanced and unbalanced grid voltage

0 signed · 23 inferred · view as graph

Inferred edges come from two machine sources: sweeps of open repository metadata (mostly SSRN and Zenodo), and a bulk OpenAlex citation snapshot. Every row below is labelled with the one it came from. Neither is a complete citation index — absence here is not evidence of absence.

Is this your work? Sign in with ORCID and put your name on the claims that are yours.
Claim with ORCID
Reference health. See whether every reference in this work resolves to a known work and none has been retracted — and get a dated CiteStamped badge you can embed.
See reference health

What this work says

Outgoing claims: the papers this work cites, builds on, or argues with.

inferredcites →https://doi.org/10.1016/j.epsr.2008.06.017openalex-snapshot
Modeling and enhanced control of DFIG under unbalanced grid voltage conditions
inferredcites →https://doi.org/10.1016/j.epsr.2008.07.005openalex-snapshot
Control strategy for a Doubly-Fed Induction Generator feeding an unbalanced grid or stand-alone load
inferredcites →https://doi.org/10.1049/el:20040299openalex-snapshot
Simple direct torque control of induction machine using space vector modulation
inferredcites →https://doi.org/10.1049/ip-epa:20060008openalex-snapshot
Proportional-resonant controllers and filters for grid-connected voltage-source converters
inferredcites →https://doi.org/10.1109/60.937200openalex-snapshot
A new approach to direct torque control of induction motor drives for constant inverter switching frequency and torque ripple reduction
inferredcites →https://doi.org/10.1109/tec.2005.853750openalex-snapshot
Modeling and Experimental Verification of Grid Interaction of a DFIG Wind Turbine
inferredcites →https://doi.org/10.1109/tec.2006.889549openalex-snapshot
Direct Power Control of DFIG With Constant Switching Frequency and Improved Transient Performance
inferredcites →https://doi.org/10.1109/tpel.2008.921157openalex-snapshot
Coordinated Control of DFIG's Rotor and Grid Side Converters During Network Unbalance
inferredcites →https://doi.org/10.1109/tpwrs.2006.889113openalex-snapshot
Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions

What points at this work

Incoming claims: where this work appears in other papers’ reference lists and arguments.

inferred← citeshttps://doi.org/10.2139/ssrn.4865266openalex-extracted
Model Predictive Control of a BCDFIG with Torque Regulation for Stand-Alone Applications
inferred← citeshttps://doi.org/10.1016/j.aasri.2012.09.046openalex-snapshot
Comparison of the Performmance of DTC of Induction Gen Nerator in Wind Energy Conversion System with PI and Neurral Controllers
inferred← citeshttps://doi.org/10.1049/joe.2014.0213openalex-snapshot
Compensation of negative sequence stator flux of doubly‐fed induction generator using polar voltage control‐based direct torque control under unbalanced grid voltage condition
inferred← citeshttps://doi.org/10.1109/eeeic.2014.6835856openalex-snapshot
Performance improvement of DFIG-based wind farm using multilevel cascaded H-bridge converter under unbalanced grid voltage conditions
inferred← citeshttps://doi.org/10.1109/icelmach.2012.6349968openalex-snapshot
A direct torque and reactive power control approach for doubly fed induction generator in wind turbine applications
inferred← citeshttps://doi.org/10.1109/icems.2017.8056486openalex-snapshot
Multiple-vectors-based model predictive direct power control of doubly fed induction generator under unbalanced grid voltage condition
inferred← citeshttps://doi.org/10.1109/jestpe.2016.2611004openalex-snapshot
Improved Predictive Direct Power Control of Doubly Fed Induction Generator During Unbalanced Grid Voltage Based on Four Vectors
inferred← citeshttps://doi.org/10.1109/npec.2018.8476703openalex-snapshot
ANFIS Based Reference Flux Estimator with GA Tuned Controller for DTC of Induction Motor
inferred← citeshttps://doi.org/10.1109/powerafrica52236.2021.9543353openalex-snapshot
Model predictive control of a doubly fed induction generator
inferred← citeshttps://doi.org/10.1109/tpel.2017.2683460openalex-snapshot
Cascaded Direct Torque Control of Unbalanced PMSM With Low Torque and Flux Ripples
inferred← citeshttps://doi.org/10.1109/tste.2014.2341244openalex-snapshot
Predictive Direct Power Control of Doubly Fed Induction Generators Under Unbalanced Grid Voltage Conditions for Power Quality Improvement
inferred← citeshttps://doi.org/10.11591/ijeecs.v5.i2.pp277-289openalex-snapshot
A Control Strategy for DFIM to Minimize DC Bus Voltage Fluctuations and Torque Oscillations
inferred← citeshttps://doi.org/10.17159/2413-3051/2019/v30i2a5658openalex-snapshot
Using normalised cross correlation and variance to determine the source of voltage unbalance exceedances in Eskom networks with wind farms
inferred← citeshttps://doi.org/10.47238/ijeca.v2i1.25openalex-snapshot
Direct Torque Control of a Doubly Fed Induction Generator
Editorial review for independent work. ICSAC — the Institute for Complexity Science and Advanced Computing — runs a structured editorial panel for researchers publishing outside journals, and publishes on CiteStamp rails. Submission is free and goes through ORCID: icsacinstitute.org/submit.